{"id":21370,"date":"2021-04-02T10:31:04","date_gmt":"2021-04-02T14:31:04","guid":{"rendered":"https:\/\/avtech.com\/articles\/?p=21370"},"modified":"2022-11-23T09:07:45","modified_gmt":"2022-11-23T14:07:45","slug":"how-to-configure-repeat-actions-in-room-alert-manager","status":"publish","type":"post","link":"https:\/\/avtech.com\/articles\/21370\/how-to-configure-repeat-actions-in-room-alert-manager\/","title":{"rendered":"How To Configure Repeat Actions In Room Alert Manager"},"content":{"rendered":"\n<p>In Room Alert Manager, you can configure your alert actions to repeat at a chosen interval, and cap the number of repetitions if desired. <\/p>\n\n\n\n<p>Follow these steps to&nbsp;configure your actions to repeat:<\/p>\n\n\n\n<ol id=\"block-2829d257-231f-4110-9fa4-9c9682d33104\"><li>Open Room Alert Manager in your web browser.<ul><li>You may open it by entering \u2018localhost:9393\u2019 or \u2018&lt;IP address of host system>:9393\u2019 in your browser\u2019s address bar. For more information, please see our FAQ,\u00a0<a rel=\"noreferrer noopener\" href=\"https:\/\/avtech.com\/articles\/19834\/\" target=\"_blank\">How to Open Room Alert Manager\u2019s Web Interface<\/a>.<\/li><\/ul><\/li><li>In order to create or edit alerts in Room Alert Manager, you must log in as an admin-level or manager-level user.<ul><li>For more information, please see the \u201cTypes of user roles\u201d section of our FAQ,\u00a0<a href=\"https:\/\/avtech.com\/articles\/20112\/how-to-configure-users-in-room-alert-manager\/#types\" target=\"_blank\" rel=\"noreferrer noopener\">How To Configure Users In Room Alert Manager<\/a>.<\/li><\/ul><\/li><li>Select\u00a0<strong>Alerts\u00a0<\/strong>in the navigation bar to the left to open the\u00a0<em>Alerts\u00a0<\/em>page.<br><img decoding=\"async\" loading=\"lazy\" width=\"220\" height=\"302\" class=\"wp-image-25158\" style=\"width: 150px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2020\/12\/RAM_Nav_Alerts.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2020\/12\/RAM_Nav_Alerts.png 220w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2020\/12\/RAM_Nav_Alerts-219x300.png 219w\" sizes=\"(max-width: 220px) 100vw, 220px\" \/><\/li><li>Next, select the alert that includes the actions you wish to repeat.<br><img decoding=\"async\" loading=\"lazy\" width=\"1062\" height=\"185\" class=\"wp-image-25161\" style=\"width: 500px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert.png 1062w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert-300x52.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert-1024x178.png 1024w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert-768x134.png 768w\" sizes=\"(max-width: 1062px) 100vw, 1062px\" \/><\/li><li>Then select the\u00a0<strong>Edit Alert<\/strong> button to open\u00a0the\u00a0<em>Alert Form<\/em>.<br><img decoding=\"async\" loading=\"lazy\" width=\"947\" height=\"531\" class=\"wp-image-25163\" style=\"width: 550px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details.png 947w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details-300x168.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details-768x431.png 768w\" sizes=\"(max-width: 947px) 100vw, 947px\" \/><\/li><li>Scroll to the <em>Then&#8230; <\/em>section, which contains the alert actions.<br><img decoding=\"async\" loading=\"lazy\" width=\"1185\" height=\"711\" class=\"wp-image-25164\" style=\"width: 550px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then.png 1185w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then-300x180.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then-1024x614.png 1024w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then-768x461.png 768w\" sizes=\"(max-width: 1185px) 100vw, 1185px\" \/><\/li><li>Select the <strong>Repeat Interval<\/strong><em> <\/em>checkbox next to the action you wish to repeat. <ul><li>Enter an interval (in minutes) to set how frequently the action will repeat. We&#8217;ve configured our action to repeat every 10 minutes.<br><img decoding=\"async\" loading=\"lazy\" width=\"1185\" height=\"711\" class=\"wp-image-25166\" style=\"width: 550px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then_Repeat.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then_Repeat.png 1185w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then_Repeat-300x180.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then_Repeat-1024x614.png 1024w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then_Repeat-768x461.png 768w\" sizes=\"(max-width: 1185px) 100vw, 1185px\" \/><\/li><\/ul><\/li><li>(Optional) You may\u00a0cap the number of times the action is performed by selecting\u00a0the\u00a0<strong>Max Repeat<\/strong>\u00a0check box.<ul><li>Enter a maximum number of repeats in the field. In our example, we\u2019ve capped the repetitions at 3.<br><img decoding=\"async\" loading=\"lazy\" width=\"1185\" height=\"711\" class=\"wp-image-25167\" style=\"width: 550px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then_Max.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then_Max.png 1185w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then_Max-300x180.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then_Max-1024x614.png 1024w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Details_Then_Max-768x461.png 768w\" sizes=\"(max-width: 1185px) 100vw, 1185px\" \/><\/li><\/ul><\/li><li>Then, select\u00a0<strong>Save Changes<\/strong> at the bottom of the screen.<br><img decoding=\"async\" loading=\"lazy\" width=\"205\" height=\"66\" class=\"wp-image-21381\" style=\"width: 125px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_SaveChanges.png\" alt=\"\"><\/li><li>In our example, when the alert is triggered, we will receive one \u201cAlert Triggered\u201d notification.<br><img decoding=\"async\" loading=\"lazy\" width=\"981\" height=\"527\" class=\"wp-image-25168\" style=\"width: 500px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Triggered.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Triggered.png 981w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Triggered-300x161.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Triggered-768x413.png 768w\" sizes=\"(max-width: 981px) 100vw, 981px\" \/><\/li><li>We\u2019ll then receive an \u201cOngoing Alert\u201d reminder every 10 minutes, which will stop after 3 times.<br><img decoding=\"async\" loading=\"lazy\" width=\"981\" height=\"527\" class=\"wp-image-25169\" style=\"width: 500px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Ongoing.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Ongoing.png 981w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Ongoing-300x161.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_Example_Alert_Ongoing-768x413.png 768w\" sizes=\"(max-width: 981px) 100vw, 981px\" \/><br><\/li><\/ol>\n","protected":false},"excerpt":{"rendered":"<p>In Room Alert Manager, you can configure your alert actions to repeat at a chosen interval, and cap the number of repetitions if desired. Follow these steps to&nbsp;configure your actions to repeat: Open Room Alert Manager in your web browser. You may open it by entering \u2018localhost:9393\u2019 or \u2018&lt;IP address of host system>:9393\u2019 in your [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"ngg_post_thumbnail":0},"categories":[287],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/avtech.com\/articles\/21370\/how-to-configure-repeat-actions-in-room-alert-manager\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How To Configure Repeat Actions In Room Alert Manager - AVTECH\" \/>\n<meta property=\"og:description\" content=\"In Room Alert Manager, you can configure your alert actions to repeat at a chosen interval, and cap the number of repetitions if desired. Follow these steps to&nbsp;configure your actions to repeat: Open Room Alert Manager in your web browser. You may open it by entering \u2018localhost:9393\u2019 or \u2018&lt;IP address of host system&gt;:9393\u2019 in your [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/avtech.com\/articles\/21370\/how-to-configure-repeat-actions-in-room-alert-manager\/\" \/>\n<meta property=\"og:site_name\" content=\"AVTECH\" \/>\n<meta property=\"article:published_time\" content=\"2021-04-02T14:31:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-11-23T14:07:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2020\/12\/RAM_Nav_Alerts.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:creator\" content=\"@AVTECHSoftware\" \/>\n<meta name=\"twitter:site\" content=\"@AVTECHSoftware\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Allie Wojtanowski\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"1 minute\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/avtech.com\/articles\/#website\",\"url\":\"https:\/\/avtech.com\/articles\/\",\"name\":\"AVTECH\",\"description\":\"Frequently Asked Questions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/avtech.com\/articles\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/avtech.com\/articles\/21370\/how-to-configure-repeat-actions-in-room-alert-manager\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2020\/12\/RAM_Nav_Alerts.png\",\"width\":220,\"height\":302},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/avtech.com\/articles\/21370\/how-to-configure-repeat-actions-in-room-alert-manager\/#webpage\",\"url\":\"https:\/\/avtech.com\/articles\/21370\/how-to-configure-repeat-actions-in-room-alert-manager\/\",\"name\":\"How To Configure Repeat Actions In Room Alert Manager - AVTECH\",\"isPartOf\":{\"@id\":\"https:\/\/avtech.com\/articles\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/avtech.com\/articles\/21370\/how-to-configure-repeat-actions-in-room-alert-manager\/#primaryimage\"},\"datePublished\":\"2021-04-02T14:31:04+00:00\",\"dateModified\":\"2022-11-23T14:07:45+00:00\",\"author\":{\"@id\":\"https:\/\/avtech.com\/articles\/#\/schema\/person\/2966f1925021087dba64df344049f189\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/avtech.com\/articles\/21370\/how-to-configure-repeat-actions-in-room-alert-manager\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/avtech.com\/articles\/#\/schema\/person\/2966f1925021087dba64df344049f189\",\"name\":\"Allie Wojtanowski\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/avtech.com\/articles\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/470c9c7fbbd3e0a96d84169645634d04?s=96&d=mm&r=g\",\"caption\":\"Allie Wojtanowski\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/21370"}],"collection":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/comments?post=21370"}],"version-history":[{"count":9,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/21370\/revisions"}],"predecessor-version":[{"id":25170,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/21370\/revisions\/25170"}],"wp:attachment":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/media?parent=21370"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/categories?post=21370"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/tags?post=21370"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}