{"id":4626,"date":"2016-05-17T13:09:33","date_gmt":"2016-05-17T17:09:33","guid":{"rendered":"http:\/\/avtech.avtechdesignworks.com\/articles\/?p=4626"},"modified":"2025-01-06T13:05:38","modified_gmt":"2025-01-06T18:05:38","slug":"configure-pings-room-alert-4e","status":"publish","type":"post","link":"https:\/\/avtech.com\/articles\/4626\/configure-pings-room-alert-4e\/","title":{"rendered":"How To Configure Pings On Room Alert 4E"},"content":{"rendered":"<p>Room Alert 4E allows you to ping up to 8 IP addresses. The Room Alert Monitor will send a ping to those addresses to check if the host is reachable. If the host is up, the ping will return as successful and register a normal state; if the host is down, or the Room Alert Monitor cannot reach it, the ping will return as failed and register an alarm state<\/p>\n<p><a href=\"#configuring_a_ping_device\">Configuring A Ping Device<\/a><\/p>\n<p><a href=\"#timing_between_pings\">Timing Between Pings<\/a><\/p>\n<h3><strong><a class=\"wpsal-anchor\" name=\"configuring_a_ping_device\" id=\"configuring_a_ping_device\"><\/a><\/strong>Configuring A Ping Device<\/h3>\n<p>To configure a ping device in your Room Alert 4E, follow the steps below:<\/p>\n<p>1. Open your Room Alert Monitor\u2019s web interface. You may open the interface using Device Discovery, Device ManageR, or your account at <a href=\"http:\/\/roomalert.com\" target=\"_blank\" rel=\"noopener\">RoomAlert.com<\/a>. You may also type the IP address of the unit directly into the address bar of your web browser.<\/p>\n<p>2. Navigate to <strong>Settings<\/strong>&#8211;&gt;<strong>Ping<\/strong>\u00a0in the navigation bar to the left to open the <em>Ping Settings<\/em> screen.<\/p>\n<p>3.\u00a0In <em>Retry Count<\/em>, you may enter the number connection attempts the Room Alert Monitor will make before an alarm condition is generated. The default is 1.<\/p>\n<p>4. In <em>Timeout<\/em>, you may enter the number of seconds to wait for a reply to the connection attempt. The default is 1.<\/p>\n<p>5.\u00a0In the <em>Ping Host Addresses<\/em> table, you may enter up to 8 IP addresses. The default for each is 0.0.0.0.<\/p>\n<p>6.\u00a0Select <strong>Save Settings<\/strong> at the top or bottom of the page. Your Room Alert Monitor will automatically reboot and commit your changes.<\/p>\n<p style=\"padding-left: 30px;\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone wp-image-4630\" src=\"http:\/\/avtech.com\/articles\/wp-content\/uploads\/2016\/05\/RA_Setings_Ping.png\" alt=\"RA_Setings_Ping\" width=\"600\" height=\"278\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2016\/05\/RA_Setings_Ping.png 1324w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2016\/05\/RA_Setings_Ping-300x139.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2016\/05\/RA_Setings_Ping-768x356.png 768w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2016\/05\/RA_Setings_Ping-1024x475.png 1024w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3><strong><a class=\"wpsal-anchor\" name=\"timing_between_pings\" id=\"timing_between_pings\"><\/a><\/strong>Timing Between Pings<\/h3>\n<p>Once the Room Alert 4E\u00a0sends a ping to a target, it waits approximately 4 seconds before sending a ping to the next target. The total interval between pings on any one target depends on how many ping devices you have set up:<\/p>\n<p style=\"padding-left: 30px;\">&#8211; If you have 1 ping device in Room Alert 4E, it will get pinged approximately every 4 seconds. The Room Alert Monitor pings the target, waits for 4 seconds, pings it again, etc. (1 ping device x 4 seconds = 4 second interval)<\/p>\n<p style=\"padding-left: 30px;\">&#8211; If you have 2 ping devices, each one will get pinged approximately every 8 seconds. The Room Alert Monitor pings the 1<sup>st<\/sup> target, waits 4 seconds, pings the 2<sup>nd<\/sup> target, waits 4 seconds, pings the 1<sup>st<\/sup> target again, etc. (2 ping devices x 4 seconds = 8 second interval)<\/p>\n<p style=\"padding-left: 30px;\">&#8211; If you have 3 ping devices, each one will get pinged every 12 seconds. The Room Alert Monitor pings the 1<sup>st<\/sup> target, waits 4 seconds, pings the 2<sup>nd<\/sup> target, waits 4 seconds, pings the 3<sup>rd<\/sup> target, waits 4 seconds, pings the 1<sup>st<\/sup> target again, etc. (3 ping devices x 4 seconds = 12 second interval.<\/p>\n<p style=\"padding-left: 30px;\">\u00a0 \u00a0&#8230;and so on&#8230;<\/p>\n<p style=\"padding-left: 30px;\">&#8211; The largest interval would be for 8 ping devices, which would each get pinged approximately every 32 seconds. (8 ping devices x 4 seconds = 32 second interval)<\/p>\n<p>The 4 second interval may be slightly protracted by the Room Alert 4E performing another action during that time: if, for example, the Room Alert 4E sends an email during those 4 seconds, the next ping would get slightly delayed until the email is finished sending.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Room Alert 4E allows you to ping up to 8 IP addresses. The Room Alert Monitor will send a ping to those addresses to check if the host is reachable. If the host is up, the ping will return as successful and register a normal state; if the host is down, or the Room Alert [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"ngg_post_thumbnail":0},"categories":[2],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/avtech.com\/articles\/4626\/configure-pings-room-alert-4e\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How To Configure Pings On Room Alert 4E - AVTECH\" \/>\n<meta property=\"og:description\" content=\"Room Alert 4E allows you to ping up to 8 IP addresses. The Room Alert Monitor will send a ping to those addresses to check if the host is reachable. If the host is up, the ping will return as successful and register a normal state; if the host is down, or the Room Alert [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/avtech.com\/articles\/4626\/configure-pings-room-alert-4e\/\" \/>\n<meta property=\"og:site_name\" content=\"AVTECH\" \/>\n<meta property=\"article:published_time\" content=\"2016-05-17T17:09:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-06T18:05:38+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/avtech.com\/articles\/wp-content\/uploads\/2016\/05\/RA_Setings_Ping.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:creator\" content=\"@AVTECHSoftware\" \/>\n<meta name=\"twitter:site\" content=\"@AVTECHSoftware\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Allie Wojtanowski\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"2 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/avtech.com\/articles\/#website\",\"url\":\"https:\/\/avtech.com\/articles\/\",\"name\":\"AVTECH\",\"description\":\"Frequently Asked Questions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/avtech.com\/articles\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/avtech.com\/articles\/4626\/configure-pings-room-alert-4e\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"http:\/\/avtech.com\/articles\/wp-content\/uploads\/2016\/05\/RA_Setings_Ping.png\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/avtech.com\/articles\/4626\/configure-pings-room-alert-4e\/#webpage\",\"url\":\"https:\/\/avtech.com\/articles\/4626\/configure-pings-room-alert-4e\/\",\"name\":\"How To Configure Pings On Room Alert 4E - AVTECH\",\"isPartOf\":{\"@id\":\"https:\/\/avtech.com\/articles\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/avtech.com\/articles\/4626\/configure-pings-room-alert-4e\/#primaryimage\"},\"datePublished\":\"2016-05-17T17:09:33+00:00\",\"dateModified\":\"2025-01-06T18:05:38+00:00\",\"author\":{\"@id\":\"https:\/\/avtech.com\/articles\/#\/schema\/person\/2966f1925021087dba64df344049f189\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/avtech.com\/articles\/4626\/configure-pings-room-alert-4e\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/avtech.com\/articles\/#\/schema\/person\/2966f1925021087dba64df344049f189\",\"name\":\"Allie Wojtanowski\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/avtech.com\/articles\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/470c9c7fbbd3e0a96d84169645634d04?s=96&d=mm&r=g\",\"caption\":\"Allie Wojtanowski\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/4626"}],"collection":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/comments?post=4626"}],"version-history":[{"count":13,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/4626\/revisions"}],"predecessor-version":[{"id":9785,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/4626\/revisions\/9785"}],"wp:attachment":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/media?parent=4626"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/categories?post=4626"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/tags?post=4626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}